GE Healthcare · MRSigna2240271224025522403082240239
Analogic 8280 Gradients Fail to Come Up with HV PS Fault.
OpenSpeed system.
Symptom
Analogic 8280 Gradients Fail to Come Up with HV PS Fault. HFO and Signa Base (SR20) systems. See Long Description OpenSpeed system running HFO3 M4 software and Signa base (SR20) systems, the gradients fail to come up ready. Have HV PS FLT on the SCA. We measured the HV at the amps and it is pretty close to zero.
Error message
2240271 Z Axis Gradient Amplifier Status. The auxiliary voltage is present but the high voltage is off. Tue Aug 3 12:11:39 2004 Error: 2240271 Host: lx-mr Process: NSP File: HPC_PORT_ID:spi_gca_error Line: 5 Z Axis Gradient Amplifier Status. The auxiliary voltage is present but the high voltage is off. Verify the "REM/LOC" switch on front panel of the System Control. 2240255 Y Axis Gradient Amplifier Status. The auxiliary voltage is present but the high voltage is off. Tue Aug 3 12:11:39 2004 Error: 2240255 Host: lx-mr Process: NSP File: HPC_PORT_ID:spi_gca_error Line: 5 Y Axis Gradient Amplifier Status. The auxiliary voltage is present but the high voltage is off. Verify the "REM/LOC" switch on front panel of the System Control. 2240308 A high voltage power supply fault occurred on the Power Supply Unit. Tue Aug 3 12:11:30 2004 Error: 2240308 Host: lx-mr Process: NSP File: HPC_PORT_ID:spi_psu_error Line: 4 Gradient Power Supply Unit Fault. A high voltage power supply fault occurred on the Power Supply Unit. Possible causes: X, Y, or Z axis amplifier has shorted the supply. 2240239 X Axis Gradient Amplifier Status. The auxiliary voltage is present but the high voltage is off. Tu
Applies to
- Models
- Signa
- Product
- HF OpenSpeed HFO1 HFO2 and HFO3 Only.
- Software
- HFO3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.