GE Healthcare · CTLightSpeed200108011230015036200108010
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Fastcal scan aborts. Problem finding a calibration vector or calibration file.
Error message
Error: 200108011 The following calibration vector is not valid: See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108011 Host: ctxm Process: scanRx File: CalStatusInfo.cxx Line: 554 Function: Data Acquisition : OC Processing The following calibration vector is not valid: kV:120 sfov:SFOV_LARGE collimation:0 spotsize:LARGE_SPOT. Error: 230015036 /usr/g/cal_db/misc/decon/8x125/cal.large_sfov.0.mdk does not exist Tue Feb 20 12:01:41 2007 Error: 230015036 Host: ct01 Process: accs File: cal_db_utils.c Line: 1065 /usr/g/cal_db/misc/decon/8x125/cal.large_sfov.0.mdk does not exist Error: 200108010 This system has not been fully calibrated for XXX kV. You will not be able to scan at XXX kV until the system has been calibrated for this kV. See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108010 Host: ctxm Process: scanRx File: SIRx.cxx Line: 2380 Function: Data Acquisition : OC Processing This system has not been fully calibrated for 120 kV. You will not be able to scan at 120 kV until the system has been calibrated for this kV.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required