GE Healthcare · CTLightSpeedVCT

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

OLC or RSE or RST remote Engineer needs to run "quicksnap" remotely. CAUTION: quicksnap should not be run during data collection. Running ""quicksnap" during data collection could cause the recon engine to fail and interrupt data collection, just wait until the exam is over before running quicksnap. The Easy way to run quicksnap is only two steps - 1 open a unix shell 2- type quicksnap then just following - instructions on the screen. OLC or RSE or RST remote Engineer needs to run "quicksnap" remotely. CAUTION: quicksnap should not be run during data collection. Running ""quicksnap" during data collection could cause the recon engine to fail and interrupt data collection, just wait until the exam is over before running quicksnap. The Easy way to run quicksnap is only two steps - 1- open a unix shell 2- type quicksnap then just following - instructions on the screen. quicksnap INFO: runtime Minimum 15 sec Maximum 120 sec, Ave 30 seconds. The customer could run quick snap from Image Works -> select Browser then the tool chest will be in the upper right had corner of the screen. In the tool chest a button for quicksnap is available. The quicksnap tool is used by engineering to collect needed timer files and various other logs from the system. The quicksnap tool can be used for data gathering when you are gather information for a PQR/PSR.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues