GE Healthcare · CTHiSpeed2300060012600050031818850152
System will not stay up in applications and shutsdown
Symptom
System will not stay up in applications and shutsdown. System will not stay up in applications and shutsdown
Error message
Error: 230006001 Process presumed down: vxmonitor-post Thu Jun 22 14:57:42 2006 Error: 230006001 Host: ls01 Process: procICE File: iceCpu.cxx Line: 360 Process presumed down: vxmonitor-post Error: 260005003 ICE CPU did not respond to polling within 180 seconds. Recon subsystem is presumed to be down. Some images may have been suspended. Thu Apr 29 06:05:11 2004 Error: 260005003 Host: fitzipct Process: procICE File: iceCpu.cxx Line: 343 ICE CPU did not respond to polling within 180 seconds. Recon subsystem is presumed to be down. Some images may have been suspended. Last ping was at Sun May 30 22:21:46 2032 with seq num 1818850152 iceConsole.log: Initializing System Memory (DRAM)... System Memory: 128MB, ECC Enabled (ECC-Memory Detected) PPC1-Bug
Applies to
- Models
- HiSpeed
- Product
- HiSpeed QX/i - GOC2 103L.5_HSQXIM4 103L.4_HSQXIM4 102L.1_HSQXIM3 HiSpeed QX/i - GOC2 Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types GOC2 List of softwares the product can run 103L.5_HSQXIM4 103L.4_HSQXIM4 - obsolete 102L.1_HSQXIM3 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2216467 Pegasus Image Generator used on LS 1.x-4.x Octane, GOC1 and GOC2. Not GRE See long description for details Part #: 2216467 Part Type: GP REPAIRABLES Part Weight: 4.41 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: FAST IMAGE GENERATOR FRU: Yes Status: Orderable Comments: FLS - PEGASUS IMAGE GENERATOR PWA CIRCUIT BOARD. USED ON HELIOS 2. MS26561 DSM 2/24/01 PCN 220318 ERRONEOUSLY CHANGEDBOARD VERSION FROM E TO G (REVISION G IS WRONG, NOTHING SHOULD BE MANUFACTURED UNDER THAT REVISION, PER PCN 220318). ADDED BY MS20544, CSV ON 1/21/02. 7/19/02- C2R COMPLETED. MS12464 4/21/03 - FEILD RESTOCK FLAG RESET TO Y. MS12575 LIST PRICE $26371.00 GELS - SECOND OPINION PROCESS TO ASK OLC IN BUC BEFORE TO SHIP INFO FROM P DE LA FUENTE /14/06/TS GA0312 EN ATTENTE DE REGUL STOCK CONTACTER GILLES ANCELOT SH CSO 0300690 ITALIE I 24810431002,PCB PEGASUS IMAGE GENERATOR PWA See example below for GOC1/GOC2 ICE box with pegasus IG board.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required