MOD drive is hung and requires reboot.
Symptom
Intermittent Inability to Attach MOD Media with Message CORRUPT MEDIA See Long Description This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Continuing inability to attach MOD media. Message is returned "Corrupt media detected". See below for an example of the errors logged in /var/log/SYSLOG and /export/home/sdc/logfiles/arslog when trying to attach MOD media. This has been a continuing intermittent problem. MOD DRIVE REPLACED 3 TIMES . SCSI CABLE AND TERMINATOR AT MOD BOTH REPLACED. MOD DRIVERS UNINSTALLED THEN RE-INSTALLED. PROBLEM OCCURS WITH NEW AND WITH PREVIOUSLY USED MOD MEDIA. The scsistat COMMAND SEES MOD DRIVE WHETHER FAULT IS ON OR NOT The FE also replaced the power supply in the SCSI tower, and the IP30 System Module in the Octane computer. The problem returned three days later. Reference SPR # MRIhc15085. From /var/log/SYSLOG Apr 18 10:13:46 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Read data recovered with ECC (asc=0x18, asq=0x1)<6>, Block #40<6> Apr 18 10:14:03 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1471397<6> Apr 18 10:14:03 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:05 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1470741<6> Apr 18 10:14:05 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:06 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1470331<6> Apr 18 10:14:06 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:10 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1471807<6> Apr 18 10:14:10 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:13 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1472381<6> Apr 18 10:14:13 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:24 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1482139<6> Apr 18 10:14:24 6A:LXMR unix: dksc1d4vol: <6> retrying request Apr 18 10:14:28 6A:LXMR unix: dksc1d4vol: <6>Recovered Error<6>: Write error (asc=0xc, asq=0x1)<6> (deferred error)<6>, Block #1483205<6> Apr 18 10:14:28 6A:LXMR unix: dksc1d4vol: <6> retrying request -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- From /export/home/sdc/logfile/arslog: MESSAGE from Process 17393>> Fri Apr 21 13:14:22 2006 (ArchiveDevice.c:3303) Attach in progress Fri Apr 21 13:14:27 2006 RetrieveDicomDirRec: grp: 20 elm: 37 DS or AN string is formatted incorrectly Fri Apr 21 13:14:28 2006 arc_attachDMOD:Checksum failure Fri Apr 21 13:14:28 2006 dmod_attach: attach DMOD failed - sdc_ddir_error=-500 Fri Apr 21 13:14:28 2006 Recovery Recommended for MID:1762881535::2005:11:30:12:54:53GMT:UTC Fri Apr 21 13:14:28 2006 Recovery original media software 'IRIX646.5__build__R2.9i' Fri Apr 21 13:15:18 2006 Recovery Rejected for MID:1762881535::2005:11:30:12:54:53GMT:UTC Fri Apr 21 13:15:18 2006 XaDisConnect: Media type 4 DETACH'd MESSAGE from Process 17393>> Fri Apr 21 13:15:18 2006 (ArchiveDevice.c:4780) [Arserver]> Archive detects corrupt media. MESSAGE from Process 17393>> Fri Apr 21 13:15:18 2006 (arsjob.c:689) Closing Arsjob MESSAGE from Process 1992>> Fri Apr 21 13:15:18 2006 (arsserver.c:425) Closing Arsjob 18 MESSAGE from Process 17389>> Fri Apr 21 13:15:18 2006 (arsjob.c:341) [Arserver]> init of arsjob connected to NETserve
Error message
10102 Archive detects corrupt media. Wed Apr 20 07:49:10 2005 Error: 10102 Host: MRS1 Process: arsjob rchiveDevice.c Line: 4780 Archive detects corrupt media. 10191 Failed Save Exam. Paused See Long Description Mon Oct 25 08:31:47 2004 Error: 10191 Host: lx-mr Process: arserverFile: arscommand.c Line: 1868 Failed save exam. Paused 2903
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.