GE Healthcare · CTHiSpeed18392128848503891265527513081394183908
79786 HiSpeed CT/i 4.X with SGI Indigo and HSA Gantry
Symptom
Scanner Hardware fault at high axial speeds. Scanner Hardware fault at high axial speeds
Error message
Error: 183921 Axial conditions at FAULT: See Long Description for complete error Mon Oct 17 08:26:48 2005 Error: 183921 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 28848/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 08:26:47:775 Log Series: 141 Axial conditions at FAULT: velocity_fb = 2662 position_fb = 50389 Formatted data: 8100 100 8 7 1 0 1 1 101 1 0 2662 -12655275 13081394 2741 2582 134 133 0x019e38 Error: 183908 Axial velocity ACCEL tracking fault See the Long Description for the full error code Mon Aug 27 09:12:45 2007 Error: 183908 Host: STC Process: Axial File: ax_error.c Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 14756/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 09:12:45:860 Log Series: 363 Axial velocity ACCEL tracking fault. current: commanded = 39990 mA current: D/A measured = 39844 mA PDU measured = 39453 mA (HW/SW Error: Retry Rx to verify probable Axial Driver or. Axial Encoder hardware problem.)
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2102012 Gantry axial motor brush and cap kit for Lightspeed 1x, CTi, HSA, HLA, and 9800 CT systems. See Long Description for details Part #: 2102012 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: FOR 9800 HLA and HSA GANTRY AXIAL MTR FRU: Yes Status: Orderable Comments: FLS - MOTOR BRUSH & BRUSH CAPS KIT. PEERLESS-WINSMITH REPLACED AS SUPPLIER BY B.D.I. 8-31-01 PERLISA GILLIAN. MS7093 KIT CONTAINS 24 PIECE PARTS, CONSISTING OF: 46-194465P22 VN#819-23-0711-0 (8 PIECES PER KIT) FRU N 46-194465P23 VN#820-07-0200-0 (8 PIECES PER KIT) 46-194465P27 VN#820-07-1300-0 (8 PIECES PER KIT) This kit includes 8 brushes and caps for gantry axial motors used in Lightspeed 1x, CTi, and HSA CT systems as well as 8 brushes and caps for gantry axial motors used in HLA and 9800 CT systems.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required