Precision 500D Iris LUT Cal Problem
Symptom
P500D During a recent PM attempted to go through imaging calibrations, and Iris LUT AV03 would not complete properly. See long description: The calibration would start normally, but as the steps advanced (steps 1 towards 22), Iris progressively closed, and the digital monitor image darkened with the change in steps (the image would stop getting darker just before the cal stopped advancing), but then it would stop advancing usually at steps 11, 14, 17, or 18. The exposure would continue but the calibration wouldn't complete. FE released exposure control, restarted exposure, and the Digital Monitor displayed an error message ""System Control error, restart exposure or reset system"". Released and restarted exposure and the cal sequence would started back at step# 1. On other attempts the steps advanced, the IUI message said calibration completed, but the Digital Monitor had an error message ""ABD value did not decrease, repeat calibration.Tried canceling out and restarting the cal, ran all Digital Diagnostics (all passed), ran QAP (passed), checked SUIF error log (error 1103012, ABD value did not decrease when Iris Xmit reduced, Digital; and error 3600044, Sys Cntrl Gitane acq reg not correct, Sys Cntrl), reseated cables, conn, and PCB's. Tried a dozen other attempts with the same results.
Error message
Error 1103012 ABD value did not decrease, repeat calibration message Error 3600044, Sys Cntrl Gitane acq reg not correct, Sys Cntrl) System Control error, restart exposure or reset system
Applies to
- Models
- Precision
- Product
- Precision 500D
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- Precision 500D Table Fluoro Carriage Front Bumper is not properly adjusted, allows excessive travel toward the front of the table.
- Precision 500D Aurora, dose readout does not update when an overhead Rad Tube Exposure is made, at any technic due to abnormally low mR/mAS from the Rad Overhead XRT.
- P500D Aurora with M4 Software (May 2006 Release), Dose Readout Correct on Console, Dose Printer Prints 0.0 due to a M4 Software Bug
- Precision 500D Aurora, RCIM E-stop circuit is difficult to troubleshoot because there is no overall interconnect schematic from the RCIM operator console to the Corona 2 board in the System Cabinet.
- Precision 500D Aurora system with Magic PC.
- P500D Siemens Collimator lamp voltage adjustment instructions missing due to documentation issues.