GE Healthcare · CT184514
78893 LightSpeed 1.X with octane and SBC console
Symptom
Axial faults with servo amp overcurrent. Overcurrent LED lights up on power up on the servo amplifier
Error message
Error: 184514 HW Error: Possible PDU (servo amplifier) or axial board problem Please see the long description for the full error code Tue Jun 3 21:13:05 1997 Suite: VACT Host: STC Proc: Control Error: 184514 File: resetServoAmp.c 1.8 Method: No Method Line: 87 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 1031 Log Series: 20 Could not clear servo amplifier fault. HW Error: Possible PDU (servo amplifier) or axial board problem
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-186852P2 A1K2 contactor See long description for details and picture Part #: 46-186852P2 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: RELAY (K2 BACK-UP CONN.) FRU: Yes Status: Orderable Comments: FLS - ALSO AVAILABLE AS 46-186852P2UUSE UP THAT STOCK FIRST! SWITCH ON SIDE OF RELAY= 46-296690P1 A4K2 PF8 TWICE FOR FE ASSIST COMMENTS!!! FOR FE ASSIST PF8 AGAIN!!! FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PARTS WHEN AVAILABLE., IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART. FLS - FE ASSIST MS6588 10/2000 46-186852P2 = AXIAL RELAY ARE YOU ORDERING THE CORRECT PART?? FOR CT PDU THE AXIAL RELAY ASMIS MADE UP OF TWO RELAYS, THE 46-186852P2 & 46-296690P1 P1 RELAY MOUNTED ATOP OF P2. 46-186852P2 = AXIAL LOOP CONTACTOR RELAY. 46-296690P1= AUXILIARY CONTAC T RELAY. SEE CTI FRU MANUAL PAGE 5-5 REVISION 26 AND ABOVE, OLDER REV DO NOT SHOW THE AUX RELAY. DO YOU STILL WHAT TO ORDER THIS PART??
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required