GE Healthcare · X-ray R&FRevolution
XRd It appears the IDC is sending uncorrected images to the AWS.
Revolution XRd Apparent Image Lag, IDC sending uncorrected images to the AWS
Symptom
XRd It appears the IDC is sending uncorrected images to the AWS. See Long Description There are so many uncorrected bad pixels in the images and the blotches look like uncorrected gain "lag".
Error message
Error 6D02 have a HW Status of 08, indicating an intermittent glitch in the communication between the AWS and the IDC: See long description: 6D02 errors have a HW Status of 08, indicating an intermittent glitch in the communication between the AWS and the IDC: ,2004-04-08,11:49:02:000,ASC,06D02,ERROR STATUS RECEIVED IN ACQUISITION STATUS MESSAG ,,,,AWS ,,,1,,1,HWStatus=0008 User=0000 ,2004-04-08,11:49:10:937,AWS,1,software failure,,WR,,Synchro,,,1,,0,the acquisition has aborted ::AWS sequence timeout fired,SynchroManager.c,960 The following sequence of errors appear several times and also look like an intermittent network communication problem: ,2004-04-08,10:28:50:312,AWS,5,communication Pb with TITAN subsystem,,WR,,TitanServer,,,1,,0,cannot send message to advantx:: sendAliveStatus,s/titanserver/src/TitanManager.c,235; ,2004-04-08,10:28:51:156,AWS,3,communication Pb with IDC subsystem,,WR,,Camera,,,1,,0,IDC socket management error ::Crash of socket IMAGE,mera/src/ClientDeviceInterface.c,124
Applies to
- Models
- Revolution
- Product
- Revolution XRd
- Component
- IDC_WS IDC _ Wallstand AWS
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…
- Revolution XRd2X Worklist query on "All Systems in this Modality" does not retrieve anything after FMI 10791A is completed due to the default query set to DX.
- Revolution XR/d error 4280 when trying to make exposure to table or wallstand detector
- Revolution XRd 2X The HP Workstation reboots itself.
- Def8000, Def5000, Revolution XRd and XRD2X Latent lead marker image burned into the detector.