GE Healthcare · CTLightSpeedVCT23000700023000701450029

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

CTx00065 Failed open DAS/Detector channel detected by PDS See Long Description for details and customer communication. CTx00065 Failed open DAS/Detector channel detected by PDS Contact customer and inform them of the PDS detected error regarding the Das/Detector and stress the importance of scheduling time with the Field Engineer to correct, before image quality is compromised. Per the PDS workflow do not close the FE PDS RFS until the issue is resolved. This does not impact the RFS - EMG metric. This Issue was detected by the Digital Services (DS) rule engine. This Issue is only applicable when detected by the Rules Engine and should not be reused in Knowlege objects for normal reactive service.

Error message

Error: 230007000 Exclusion Test - Row 48:16B, Channel 552, Module 35 Open Channel* FAILED Z-AXIS EXCLUSION See LD for complete error. Tue Jul 19 03:54:27 2005 Error: 230007000 Host: ct01 Process: badchanmgr File: BadChannelMap.cxx Line: 533 Exclusion Test - Row 48:16B, Channel 552, Module 35 Open Channel* FAILED Z-AXIS EXCLUSION CRITERIA *.

Error: 230007014 Uncorrectable detector channels have been found for scan See LD for an example of entire error message. Fri Oct 28 09:32:03 2005 Error: 230007014 Host: presbyplano Process: badchanmgr File: badchanmgr.cxx Line: 1194 Uncorrectable detector channels have been found for scan 50029/2/2

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5143018 VCT HALO DIFB (Digital Interface Board) See long description for details If no stock of 5143018 Can use P/N 5194006-3 on Halo Detector Part #: 5143018 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: HALO DIFB PWA FRU: Yes Status: Orderable Comments: ** FE ASSIST ** If no stock of 5143018 Can use P/N 5194006-3 on Halo Detector (11/3/09 212001261) Activated per Expert Case/FEMC Case #6717276 212008958 10-25-07.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.