Pular para o conteúdo principal
GE Healthcare · MR2252301

Unable to Scan using the USAI Large Knee Coil Legend 5000 Phased Array Knee and Foot Coil MCAT M2087E due to Error Code…

Unable to Scan using the USAI Large Knee Coil Legend 5000 Phased Array Knee and Foot Coil MCAT M2087E due to Error Code 2252301 Multicoil Bias Fault Detected Open Circuit.

Symptom

Unable to Scan using the USAI Large Knee Coil Legend 5000 Phased Array Knee and Foot Coil with 2252301Multicoil Bias Fault Detected Open Circuit See Attachment for all details.

Error message

2252301 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCDx Channel x of y, counting from 1 Value x mA Limit y mA See Long Description for Extended Error 2252301 MRI_GB_OW0 NSP SCP:DCB 816 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 (or MCD2) Channel 1 of 16, counting from 1 Value: 2 mA Limit: 298 mA Mask of failed channels: 0x1 Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B-> Extended Error: This fault was detected by the Driver Module. An open circuit fault occurs when the actual value is less than the pre-defined limit. Check system cables, connectors, coils and configurations. Re-seat all coil connectors. The mask of all failed channels indicates additional channels with the same fault - convert the hex number to a bitmap to decipher the mask, with channel 1 indicated by the least significant bit and channel 16 indicated by the most significant bit. For example, a mask of 0x3c converts to 0011 1100, meaning channels 3, 4, 5, and 6 all experienced the same failure. The key at the bottom of the error message shows the MC driver bias channels provided by the Driver Module used with each mult

Applies to

Product
Open Speed with EXCITE For HFO4 and HFO5 only
Software
OPENMR5-HFO5 Open Speed with Excite Product
Component
2264742-14 0.7T EXTREMITY COIL CABLE--LARGE
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues