Pink pop up message saying The system has been configured to recognize a Performix Tube

Symptom

Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days. See Long Description for full text of message. Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days Tube type at the end of the first sentence in message below can vary. The system has been configured to recognize a GE Medical Systems Tube. A 30 day period from the date of tube installation has been granted to allow time to manually verify the tube identity. Please call GE Medical Systems to dispatch a Field Service Engineer (FSE) to verify the tube configuration. Please allow a minimum of 10 days for the FSE to schedule verification. Verification should take no more than 30 minutes. If a GE Medical Systems FSE does not verify the tube identity within %s days, the system will revert to an "unrecognized tube" status, resulting in the following: - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.

Error message

Error: 200109172 Tube verification reminder: The system has been configured to recognize a GE Medical Systems Performix tube for a 30-day period. Error: 200109172 Host: ls16 Process: scanRx File: SIRx.cxx Line: 619 Function: Data Acquisition : OC Processing Tube verification reminder: The system has been configured to recognize a GE Medical Systems Performix tube for a 30-day period. Error: 200109172

Error: 200109173 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Mon Jul 31 15:13:28 2006 Error: 200109173 Host: ls16 Process: scanRx File: SIRx.cxx Line: 623 Function: Data Acquisition : OC Processing Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Error: 200109173 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Mon Jul 31 15:13:28 2006 Error: 200109173 Host: ls16 Process: scanRx File: SIRx.cxx Line: 623 Function: Data Acquisition : OC Processin

Applies to

Models
LightSpeed, VCT, BrightSpeed
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.