GE Healthcare · CTLightSpeed23001900678643520185230011036
73539 LightSpeed 5.X 60KW G-DAS16 with GRE
Symptom
Scanner Hardware Shutdowns and Recon problems Lots of error messages dealing with Scan Disk Array, missing images, deleted and removed header files.
Error message
Error: 230019006 A non-zero errno was encountered during a remote system call. See Long Description for variable error content Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: read errno: 5 [ Input/output error ] sequence: 2662 Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: mkdir errno: 786435 [ S_ioLib_DEVICE_ERROR ] sequence: 20185 Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: raw_file_allocate errno: 28 [ No space left on device ] sequence: 29 Wed Oct 13 18:25:08 2010 Error: 2300190
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2362873 SDDA (Scan data disk array) used on GOC3. See Long Description for details. The GOC3 to GOC4 upgrade kits are now under 1 part number, 5144058-500 plus the FE will have to also order the DARC2 that is needed by the DAS as a separate order. Part #: 2362873 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: SCAN DATA DISK ARRAY - GRE FRU: Yes Status: Orderable Comments: OBSOLETE PART case 8391074 This part has been identified as obsolete and no short-term solution has been identified FE must identify and order a higher or lower level spare part as required Contact your support engineer on-line engineer or Parts ID team should you require support 212012173 05-23-07 ** FE ASSIST ** For CT not PET.. IF no stock of 2362873 SDDA must upgrade to DARC II + ICOM Kit per one of the following part number's * 5144058-500, 16 MDAS 16,8,4 GDAS DARC Replacement kit, JARRELL * 5144058-501, 4,8 MDAS DARC Replacement Kit, JARRELL * 5144058-502, 4 SDAS DARC Replacement Kit, JARRELL Documentaion 5194645-100 Must order software release 06MW29.7, p/n 5193989 and perform a LFC to support this FRU if system is not currently running 06MW29.7 or better (2/19/07 212001261) *** 2ND OPINION NOTES *** Look at the DARC messages log for SCSI disk errors located at /var/log/messages
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required