GE Healthcare · CTLightSpeed26010011050070

LightSpeed 5.X (80/100kW)

Symptom

"Scan hardware Stopped Scan" with PDU errors "Scan hardware Stopped Scan" with PDU errorss

Error message

Error: 260100110 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0. -OR YOU MAY SEE- The PDU Kss Contactor has NOT closed in the alloted time. Timeout:300 msec Timer:0 msec Contactor Status: Open Error: 260100110 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0.Tue Jul 27 18:25:12 2004 Error: 260100110 [insite@hvllct01 ~]$ /usr/g/insite/bin/viewlog Host: tgp Process: tgp subsys File: scHvdcMgr.c Line: 307 Tue Jul 27 18:25:13 2004 Host : Table Gantry Processor Ermes # : 260100110 Exception Class : Abort Severity : Primary File : scHvdcMgr.c Line# : 307 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Scout Scan: 4949/1/1 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0. This error is flagged by Table Gantry Processor on the SYSTEM MONITORING : HVDC Monitor. ---------Similar error below but for Axial Scan------------ Tue Feb 7 07:50:11 2006 Error: 260100110 Host: tgp Process: tgp_subsys File: scHvdcMgr.c Line: 328 Tue Feb 7 07:50:11 2006 Host : Table Gantry Processor Ermes # : 260100110 Exception Class : Abort Severity : Primary File : scHvdcMgr.c Line# : 328 

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2334820-3 replaces 2334820-2 PDU control board Used by BSD,HD,VCT, RT,LS,CJ and PET(BSD) with NGPDU or NGPDU-4 See LD for details 2334820-3 replaces 2334820-2 PDU control board Used by BSD,HD,VCT, RT,LS,CJ and PET(BSD) with NGPDU or NGPDU-4 Part #: 2334820-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: NGPDU control board FRU: Yes Status: Orderable Comments: 30 Aug 2011 promoted for ECR2122276.305024364
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues