GE Healthcare · CTHiSpeed200501536200105007200001821200501520200000019
Unable to prescribe an exam
Symptom
Unable to prescribe an exam
Error message
Error: 200501536 Previous message error was of type Get Calibration Status Request with sequence number 6159 See Long Description for the full error Thu Jun 9 08:19:31 2005 Error: 200501536 Host: pmct Process: scanRx File: uifIpcMgrScanRx.c Line: 7070 Function: Data Acquisition: OC Processing Previous message error was of type Get Calibration Status Request with sequence number 6159 Error: 200105007 Scanner software failed to process message with status 200001821 while Getting Cal Status See Long Description for the full error examples. status and process may change Thu Jun 9 08:19:31 2005 Error: 200105007 Host: pmct Proces: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition: OC Processing Scanner software failed to process message with status 200001821 while Getting Cal Status Another example: Wed Apr 5 15:24:48 2006 Error: 200105007 Host: bhicct1 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition : OC Processing Scanner software failed to process message with status 200501520 while Enabling Landmark Another Example Tue Jun 24 05:41:44 2008 Error: 200105007 Host: rhapby26 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition :
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required