Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT23001900678643520185

Scanning aborted with scan data error

Symptom

"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors

Error message

Error: 230019006 A non-zero errno was encountered during a remote system call. See Long Description for variable error content Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: read errno: 5 [ Input/output error ] sequence: 2662 Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: mkdir errno: 786435 [ S_ioLib_DEVICE_ERROR ] sequence: 20185 Error: 230019006 Host: dhmcvct Process: accs File: sdio_proxy.c Line: 323 A non-zero errno was encountered during a remote system call. The system call may have failed to complete successfully or may have been interrupted. The following diagnostic information was returned. function: raw_file_allocate errno: 28 [ No space left on device ] sequence: 29 Wed Oct 13 18:25:08 2010 Error: 2300190

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues