Symptom

warning: the sbc disk is over 90% full run storelog intermittently during morning boot up on CTi Indigo system Problem: warning: the sbc disk is over 90% full When system is booted up a warning message appears on the monitor that the sbc disk is over 90% full. Some times the system will go to application and then drop down to boot level. May also get run storelog message (which will not fix this problem)and customer may also report that the system seems to run slowly. rsh to sbc and df to show disk status shows root partition at 100% root @ MICB_sbc0 6: df Filesystem kbytes used avail capacity Mounted on /dev/sd0a 16079 14409 62 100% / /dev/sd0d 24127 9841 11873 45% /usr /dev/sd0f 221375 92004 107233 46% /usr/g

Applies to

Models
HiSpeed
Product
HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2124215 (BIT 3) GIO64BUS TO VMEBUS CARD SET Used in CTi Rhapsode SGI Indigo computer Part #: 2124215 Part Type: GP REPAIRABLES Part Weight: 3.99 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: VMEBUS CARD ASSEMBLY INCLUDING: FRU: Yes Status: Orderable Comments: *** OBSOLETE PART *** This part has been identified as obsolete and no short-term solution has been identified. FE must identify and order a higher or lower level spare part as required. Contact your support engineer, on-line engineer or Parts ID team should you require support. 212012173 10-2-06 GELS - IMPORTANT SEE D915. VME BIT3 BOARDS DIRECT FROM BIT3 (I.E. - GPO STOCK) WILL *NOT* BERJUMPERED CORRECTLY FOR CT/I. MATCH THE OLD BOARD BEING REPLACED ORUSE THE CT/I JUMPER DOCUMENT BEING DISTRIBUTED. L.KRISBER,BIT 3 CRD SET VMEBUS CARD ASSEMBLY INCLUDING: STANDARD 6U VMEBUS ADAPTER CARD SUN STYLE 6U TO 9U ADAPTER W/AIRDAM SUN FRONT PANEL W/EMC SPRING FINGERS LED~S MOUNTED ON THE SUN FRONT PANEL VIA ELECTRICAL HARNESS 6U TO FRONT PANEL CABLE & CONNECTORS 2124215-2 BIT3 GI064BUS CARD ADAPTER Used in CTi Rhapsode SGI Indigo computer EQUIVALENT: T3202HZ G1064 BUS CARD ADAPTER Used on RHAPSODE INDIGO 2 COMPUTER PART NUM: 2124215-2 ALTERNATE: RPQ600763 EQUIVALENT: T3202HZ Find the replacement procedures in the following link to CDL: DIRECTION 2152922-100 CT/I SYSTEM SERVICE MANUAL - ADVANCED Link to the Renewal Parts Manual on CDL: Direction 46-018316 CT HiSpeed Systems Field Replaceable Units (FRU)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues