GE Healthcare · CT200105007200001821200501520200000019200108008200501536
Lightspeed 1.X - Octane
Symptom
Unable to prescribe an exam
Error message
Error: 200105007 Scanner software failed to process message with status 200001821 while Getting Cal Status See Long Description for the full error examples. status and process may change Thu Jun 9 08:19:31 2005 Error: 200105007 Host: pmct Proces: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition: OC Processing Scanner software failed to process message with status 200001821 while Getting Cal Status Another example: Wed Apr 5 15:24:48 2006 Error: 200105007 Host: bhicct1 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition : OC Processing Scanner software failed to process message with status 200501520 while Enabling Landmark Another Example Tue Jun 24 05:41:44 2008 Error: 200105007 Host: rhapby26 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition : OC Processing Scanner software failed to process message with status 200000019 while Gett ing Tube State Error: 200108008 You will not be able to scan because no calibration information is available See the long description for the full error code Thu Jun 9 08:19:31 2005 Error: 200108008 Host: pmct Process: scanRx File: SIRx.cxx Line: 1307 Function: Data Acquisition: OC Processing F
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required