LightSpeed 4.X - Octane
Symptom
Application software failed to boot with insufficent disk space message. Application software failed to boot with out of disk space message. See the long description for error codes from viewlog and SYSLOG Application software failed to boot with out of disk space message Thu Jun 23 07:02:15 2005 Error: 9071 Host: gtct3 Process: dbrserver File: proc.c Line: 376 get mail failed in process_mail() Thu Jun 23 07:02:15 2005 Error: 9056 Host: gtct3 Process: dbrserver File: server.c Line: 52 connection to Netserver failed, exiting... SYSLOG in /usr/adm: Jun 23 07:15:01 2C:gtct3 sendmail[2125]: NOQUEUE: SYSERR(root): queuename: Ca nnot create "qfHAA02125" in "/var/spool/mqueue" (euid=0): No space left on device Jun 23 08:28:45 3E:gtct3 ctuser: checkdisk: Disk partition /dev/usr is full (on gtct3).
Error message
Error: 200002744 Imagecreate traceback Fri May 27 09:40:15 2005 Error: 200002744 Host: ct2 Process: imagecreate File: ic_mfm_main.c Line: 255 Imagecreate traceback
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - Octane sw_version: 405I.2_H4.0M5 LightSpeed 4.X - Octane Gantry Model # 2339985 Console Model #'s 2341923 and 2341923-2(D3D) check_config shows LightSpeed 16 / LightSpeed 16 Product: LightSpeed16 sw_version: 405I.2_H4.0M5 or newer machine_type: Octane host_id: 3232297858 tube_type: 15 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 405I.2_H4.0M5 for LightSpeed 4.X (LightSpeed 16) with H16 Console (GOC1)(2341923, 2341923-2) - showprods returns 405I.2_H4.0M5 for LightSpeed 16 with GOC1 SGI Octane CPU 405I.2_H4.0M5 for LightSpeed 16 with GOC1 SGI Octane CPU Class C Class M Application Software Set CD Part No. Ver. CD Label CD Part No. Ver CD Label Set Part No. Apps. CD Part No Apps. CD Label showprods/ Service Desktop Intro. Date Comment 2395172 1104I.2_ H4.0M5 CLASSC LightSpeed MDAS 4/8/16/ HiSpeed QXi Class C Software 2395173 1204I.2_ H4.0M5 CLASSM LightSpeed/ HiSpeed QX/I Class M Software 2395176 2395170, 2395171, 2399867 LightSpeed 16 Applications Software (Disk 1, Disk 2 and Patch A) 405I.2_H4.0M5 FW47-03 LS2002M5. IRIX only. Class C/M Common w/ LS 2X, 3X, & 4X.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.