GE Healthcare · CTLightSpeedVCT260107215260107217260107214
62267 LightSpeed 5.X 60KW GDAS16
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260107215 Axial Motor Control (AMC) Logic could NOT position the Gantry See long description for full error Fri Jan 6 14:13:53 2006 Error: 260107215 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 1662 Axial Motor Control (AMC) Logic could NOT position the Gantry, Retry Rx to verify probable Gantry Balance or Brake or Encoder Hardware. Error: 260107217 axial motor control detected gantry motion without command See the Long Description for the full error code Wed Mar 23 10:01:01 2005 Host: Table Gantry Processor Ermes #: 260107217 Exception Class: Abort Severity: Primary File: amc_mon.c Line#: 1059 Function: AXIAL CONTROL: Axial Control Scan Type: Scout Scan: 1033/1/1 Axial Motor Control (AMC) Logic detected Gantry (Axial) MOTION without Command Current Position: 91.3 degs Commanded Position: 90.0 degs Degrees Tol: +/- 1 Retry Rx to verify probable Gantry Balance or Brake or Encoder Hardware problem Error: 260107214 Gantry Failed to Stop at Position XX degrees within XX.X seconds See Long Description for complete error Thu Sep 22 13:19:47 2005 Error: 260107214 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3687 Thu Sep 22 13:19:47 2005 Host : Table Gantry Processor
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP, VCT, and HD750. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) See LD for details 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP and VCT. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) Part #: 5311936 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Shipping collector for Axial Encoder Assembly. FRU: Yes Status: Orderable Comments: Per ECR 2058601, 212008898, 10/8/08
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required