Lightspeed 1.X - Octane

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183902 PDU AMPLIFIER Fault See LD for complete error Error: 183902 PDU AMPLIFER Fault Fri Mar 31 08:47:42 2006 Error: 183902 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 31194/1/2 Type: Scout Exception Level: Pri/Most Severe Time: 08:47:41:220 Log Series: 351 PDU AMPLIFIER Fault. current: commanded = -29735 mA current: D/A measured = -30077 mA PDU measured = -26171 mA HW Error: Retry Rx to verify probable servo amplifier hardware problem

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-297910P1 AXIAL SERVO AMPLIFIER, 150V, 40A, - (Allen Bradley, used on CTi, LS 1.X HiSpeed QXi) See long description for details 46-297910P1 Axial Servo Amp, 150v 40a (Allen Bradley - used on CTi, LS1x, HS QXI) Please see note at the bottom Part #: 46-297910P1 Part Type: GP REPAIRABLES Part Weight: 14.55 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL SERVO AMPLIFIER, 150V, 40A, FRU: Yes Status: Orderable Comments: FLS - FRU 1. AB SERVO AMP FOR HSA. FUTS FW 26'93. Note: Allen Bradley servo controller please check the gain adjustment pot. Check the settings from the old one to the new one. The old one was set to 50. When FE set the new one to that value the servo amp started to work. Original failed with over current indications. FE found one of the three glyptol sealed adjustment pots out of adjustment from the repair facility. The gain pot was set to 70 when it should have been set to 50. Set the gain pot to 50 and the servo controler pn 46-297910P1 started to work properly. 46-321138G1 AXIAL IF BOARD See long description for details 46-321138G1 Part #: 46-321138G1 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: AXIAL IF BOARD FRU: Yes Status: Orderable Comments: FLS - AXIAL INTERFACE BD......... FOR HSA. FUTS FW 26 '93. NOTEFE..DO TO PUBLICATION ERROR USE PART# T3202EF IF YOU WANT A ALLEN BRADLEY SERVO AMP...USE T3202CK IF YOU WANT A WEST AMP SERVO AMP..WIL GARCIA(3036) PARTS-ID 10/11/96 H: EAC SELLS THESE TO ON-LINEPOWER V/C 003004 TO BUILD THE PDU. AS A LAST RESORT YOU MAYBE ABLE TO SOURCE ONE FROM THEM. MS4636 1/30/98
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.