PM Check Fails with the Message THE GAP BETWEEN SPT & LVS PM DATA FILES IS MORE THAN A DAY, Exiting.
Symptom
PM Check and thus IBIS Fails for LVShim, but the Data Passes and SPT and LVShim were run within 24 hours of each other PM Check, and thus IBIS, fails for LVShim but we don't know why, the data passes and the gap between SPT and LVShim was less than a day. In fact, the gap between the two tests was only eighteen minutes. We can see this in the time stamp on the files in /usr/g/service/data. Why then do we have this failure? -------------------------------------------------- Contents of PM_history file -------------------------------------------------- ***************************************************************** PM Assist Status : PM complete. ***************************************************************** SPT PM File Name : /usr/g/service/data/GCJK3353_PM.SPT ---------------------------------------------------------------- Head SNR : PASS Head FSE Stab : PASS Head GRE Stab : PASS Body SNR : PASS Body FSE Stab : PASS Body GRE Stab : PASS Coherent Noise : PASS Eddy Current X : PASS Eddy Current Y : PASS Eddy Current Z : PASS LVS PM FILE NAME : /usr/g/service/data/GCJK51RC.LVS ---------------------------------------------------------------- LV Shim : FAIL EPI White Pixel PM FILE NAME : /usr/g/service/data/G4OJ3913_PM.EPT ------------------------------------------------- Head White Pixel : PASS Body White Pixel : PASS Please Fix the SEVERE Failures (except for EPIWP tests ) before : 1/9/2007 Last & Next scheduled PM dates --------------------------------- LAST PM DATE : 12/19/2006 Next PM is DUE by : 2/28/2007 PM Status: ON TIME
Error message
THE GAP BETWEEN SPT & LVS PM DATA FILES IS MORE THAN A DAY, Exiting PM Check Failure. THE GAP BETWEEN SPT & LVS PM DATA FILES IS MORE THAN A DAY, Exiting
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.