Pular para o conteúdo principal
GE Healthcare · CTHiSpeed185557185505

HiSpeed CT/i 4.X with Indigo and HSA Gantry

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 185557- hemrc serial link is down. Hemrc_+12V failure detected. Possible causes: HEMRC fuse (F5), Interconnects, HEMRC AC Drive, HEMRC Control Board See Long Description for complete error Mon Jul 24 08:41:32 2006 Error: 185557 Host: OBC Process: Generator File: scanbusDriver.c 1.5 Line: 243 Function: XRAY GENERATION : Tube Rotor Control Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 08:41:28:915 Log Series: 31 Could not send HEMRC message in the allotted time. HEMRC serial link is down. HEMRC_ISO_+12V Failure detected. Possible causes: HEMRC fuse (F5), Interconnects, HEMRC AC Drive,

Error: 185505 Could not send HEMRC message in the allotted time. HEMRC serial link is down. HEMRC_ISO_+12V indicates OK.

Applies to

Models
HiSpeed
Product
HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2144699 HEMRC ASSEMBLY- CT/i Performix See long description for further details. Part #: 2144699 Part Type: GP CONSUMABLES Part Weight: 40.46 LBR Repairable: No Returnable: No Hazardous Material: N Description: HEMRC ASSEMBLY FRU: Yes Status: Orderable Comments: **Please consider ordering the used part when it is appropriate for your customer. It will save you substantial money.** FLS - HIGH EFFICIENCY MOTOR ROTOR CONTROL ASM USED ON FAST RHAPSODE M3 FW 28 7/1/97 GWENN08992. PDV SINCE MFG'S STOCK IS NOT INDIVIDUALLY PACKAGED. MS13128 3/25/98 PC C1 TO C3. CD&S NOTE: IF OUT OF STOCK, HOTLINE FROM CT MFG IF VENDOR CAN'T DROP-SHIP PROMPTLY. IT IS STILL CURRENT TO MFG, BUT CT MFG'RG WON'T PACK THESE FORGPO STOCK ANYMORE. MS7093 DIMS: 21 X 21 X 20 W/SKID 24 X 36 X 26 AND WEIGHT FLS - FE ASSIST MS6588 2/16/99 2144699 = HEMRC ASSEMBLY HEMRC ASSEMBLY SHOULD BE BROKEN DOWN TO A LOWER LEVEL FRU. MAKE EVERY EFFORT TO TROUBLE SHOOT THE HEMRC DOWN TO A LOWER LEVEL FRU. REFER TO FRU MANUAL HEMRC ASSEMBLY CTI PAGE 1-68. CONTACT THE ONLINE CENTER FOR ASSISTANCE IN TROUBLE SHOOTINGDOWN TO A LOWER LEVEL FRU. ** DO YOU STILL WANT TO ORDER THIS PART????
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues