Pular para o conteúdo principal
GE Healthcare · CTLightSpeed260115206506528101635920390

LightSpeed 5.X (60kW)

Symptom

Table is lowering on its own with Uncommanded elevation motion. motor controller detects uncommanded motion. - document in RFS - critical issue Table is lowering on its own with Uncommanded elevation motion. motor controller detects uncommanded motion. Problem is becoming less intermittent and exam sometimes proceeds normally once the resume button is selected. The problem also occurs more frequently when patient is heavy. ct01% /usr/g/insite/bin/viewlog Tue Aug 10 19:04:09 2004 Error: 184836 Host: ETC Process: Elevation File: elev scan.c 1.17 9/30/92 Line: 178 Function: No System Function Reported Scan: 4530/2/7 Type: Helical Exception Level: Pri/Most Severe Time: 19:04:08:905 Log Series: 376 motor controller detects uncommanded motion. Aborting any active scan

Error message

Error: 260115206 Elevation moved without command or position changed by characterization. See LD for more details Sat Nov 25 07:59:43 2006 Error: 260115206 Host: tgp Process: tgp_subsys File: mtcb_emc_motion_check.c Line: 74 Sat Nov 25 07:59:44 2006 Host : Table Sub-System Ermes # : 260115206 Exception Class : Secondary Severity : Pri/Soft File : mtcb_emc_motion_check.c Line# : 74 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Elevation moved without command or position changed by characterization. Current position = 506528 um Last stop position = 1016359 um Tolerance = 5000 um Time since last stop = 20390 msec Hardware status = 0x7088 Target position = 506528 um

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2100671 CT TABLE GAS SPRING - Used on ALL HSA, CTi, LightSpeed 1.X through 5.X tables Part #: 2100671 Part Type: GP CONSUMABLES Part Weight: 1.40 LBR Repairable: No Returnable: No Hazardous Material: N Description: CT Table gas spring FRU: Yes Status: Orderable Comments : FLS - REPLACES 46-327064P1 & 46-296891P1 PER PCN 161843 7-20-93 MS4398. NOT ON SSS: SUSPA IS NOT SUPPLIER. TOOL FOR REPLACING GAS SPRING IS 2144261 ************************************************************PART HAS BEEN DE-LISTED AS A HAZARDOUS MATERIAL ITEM. PART IS NOT HAZARDOUS FOR ANY MODE OF TRANSPORTATION. HAZARDOUS PAPERWORK IS NOT NEEDED. 4/99 ************************************************************ ALSO USED ON QXI LIGHTSPEED ALSO USED ON LIGHTSPEED GELS - "NON FLAMMABLE GAS - HAZ IATA DESC. ""ARTICLES, PRESSURIZED, PNEUMATIC "" UN 3164 - CLASS 2.2",GAS SPRING HAZ #8 is the shock
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.