GE Healthcare · CTLightSpeed200002352200501502
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
System would shutdown on bootup to Apps
Error message
Error: 200002352 A HOST_SHUTDOWN was initiatied by the death of msgView See Long Description for full Error Tue Jan 4 17:31:42 2005 Error: 200002352 Host: ct1_076 Process: cupMonitor File: ssProcStop.c Line: 765 A HOST_SHUTDOWN was initiatied by the death of msgView Error: 200501502 UifXIoErrorHandler: Encountered an X library I/O error. errno = xx Process will intentionally dump core. See Long Description for a complete error. Tue Nov 8 12:03:08 2005 Error: 200501502 Host: ct03 Process: environmentMgr File: UifXErrorHandlers.c Line: 124 Function: No system function reported UifXIoErrorHandler: Encountered an X library I/O error. errno = 32 Process will intentionally dump core.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-15 Octane1 graphics card XIO MODULE / SGI# 013- 1600- 005 2169940-15 Octane1 graphics card XIO MODULE / SGI# 013- 1600- 005 2169940-15 Octane1 graphics card XIO MODULE / SGI# 013- 1600- 005 Part #: 2169940-15 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: SPARE XI0 MODULE FRU: Yes Status: Orderable Comments: FLS - SPARE XIO MODULE U/O NEXGEN 12/97 GWENN MS08992ALSO AVAILABLE AS A UU PART HQ: M3 FW 22 '98 THIS VENDOR HAS A 30 DAYS CONTRACT DO NOT TOLERATE PO'S BEING PUSHED OUT BEYOND THE 30 DAYS. MS08992 GWENN 11/98 ALSO USED ON LX2 PER JIM SELIG 1/99 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA 2169940-37 4MB Textured Memory 2169940-37 4MB Textured Memory See LD for Picture 2169940-37 4MB Textured Memory
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.