Pular para o conteúdo principal
GE Healthcare · CTBrightSpeed2601152414889740260115217

Table does not respond to console or keypad commands

Symptom

Table does not respond to console or keypad commands

Error message

Error: 260115241 MTCB cradle invalid Pacsci drive model set. Invalid cradle current Model = xxxxxxx See LD for complete error Fri Oct 14 10:18:27 2005 Error: 260115241 Host: tgp Process: tgp_subsys File: mtcb_cmc_drv_req.c Line: 941 Fri Oct 14 10:18:28 2005 Host : Table Sub-System Ermes # : 260115241 Exception Class : Soft Severity : Pri/Soft File : mtcb_cmc_drv_req.c Line# : 941 Function : No System Function Reported Scan Type : None/Unknown Scan: 232/1/0 MTCB cradle invalid Pacsci drive model set. Invalid cradle current Model = 4889740

Error: 260115217 No response from serial device (Cradle or Elevation Drive) See LD for a sample of full error. Fri Oct 14 10:18:27 2005 Error: 260115217 Host: tgp Process: tgp_subsys File: pacsci_actions.c Line: 284 Fri Oct 14 10:18:28 2005 Host : Table Sub-System Ermes # : 260115217 Exception Class : Soft Severity : Pri/Soft File : pacsci_actions.c Line# : 284 Function : No System Function Reported Scan Type : None/Unknown Scan: 232/1/0 No response from serial device (Cradle drive) seq num 94 reply needed 0 command ff04 This same error could say "No response from serial device (Elevation Drive)"

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2342729-3 Elevation or Cradle Drive Amplifier used on the 5.X table - same driver amp is used for both See LD for additional part information Part #: 2342729-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: H-POWER TABLE SERVO DRIVE, EMC EDITION 2 COMPLIANT FRU: Yes Status: Orderable Comments: **Please consider ordering the used part when it is appropriate for your customer. It will save you substantial money.** Part added per DST-HP60 16 slice RSPL. 040906 MS13452.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues