Cold Head Cycling Is Disabled During Scan.
Symptom
Cold Head Cycling Is Disabled During Scan. The system is an OpenSpeed running HFO3 M4 software. Coldhead cycling is disabled, so the 2 stage coldhead runs during scanning. There are SHEM communication errors in the /usr/g/service/log/tcuErrors log. I can telnet between the SHEM and the system, so it looks like network connection is good. The MAGNET_MONITOR_IP line is configured with the SHEM IP address in /etc/hosts on the MR. Ran /MVServe/bin/Net_Config on the SHEM. Looks OK. See long description for more info: /usr/g/service/log/tcuErrors log: 12/23/2003 11:49: PMHost.cc:476 CH Status unchanged: Previous Status = Communication Fail, Current Status = Communication Fail 12/23/2003 11:51: PMColdHead.cc:29 Comm with SHeM failed errors in gesys log: Tue Dec 23 12:17:25 2003 Error: 2225113 Host: lx-mr Process: NSP File: HPC_PORT_ID:hpc_change_state Line: 40 ColdHead switching not enabled during scan. HPC was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains. {sdc@lx-mr}[1] getver Hostname : lx-mr Build number for MrpApps is HFO3.29I_M4_0320.a Build number for PostSdC is HFO3.29I_M4_0320.a Build number for cclass is HFO3.29I_M4_0320.a Build number for driverSupport is HFO3.29I_M4_0320.a Build number for insite is HFO3.29I_M4_0320.a Build number for install is HFO3.29I_M4_0320.a Build number for os_cd is 6_15.4.a Build number for pc is HFO3.29I_M4_0320.a MR Software release: H.F.O.3.0320a
Error message
2248715 ColdHead switching not enabled during scan. SCP was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains.
Applies to
- Product
- HF OpenSpeed HFO1 HFO2 and HFO3 Only.
- Software
- HFO3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.