GE Healthcare · CTLightSpeed1824271203314660
LightSpeed 4.X - GRE
Symptom
Table elevation moves tiny increments and stops. Table elevation moves tiny increments and stops
Error message
Error: 182427 Gantry Back / Forward Touch Sensor Error See Long Description for complete Error Error: 182427 Gantry Tilt Back or Gantry Tilt Forward Sensor Error Error: 182427 Host: ETC Process: Elevation File: emcTouchSensor.c Line: 125 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 12033/1/0 Type: None/Unknown Exception Level: Pri/Soft Time: 14:58:23:525 Log Series: 344 The Gantry BACK Touch Sensor Error : Console Pushbutton Remote Tilt is DISABLED. Use Gantry Controls to Tilt the Gantry. Current Position 14660 (.01 mm). Elev Dir: 1 (0 = Up 1 = Down) (Elev Cmd: 1 TouchSensor: 0x8000). Same Error for the Forward Touch sensor
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2277404 Patient Tilt Sensor, Large for Rear Gantry Cover used on HiSpeed QXi, 2.x(Plus), 3.x(Ultra), 4.x(16 Slice), HPower and VCT gantries See Long Description for Part Details 2277404 Patient Tilt Sensor, Large for Gantry REAR Cover Asm. Part #: 2277404 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PATIENT TILT SENSOR, LARGE FRU: Yes Status: Orderable Comments: FLS - H2 GANTRY. COMMON TO MFG MS26561 DSM 1/7/01 REAR LARGE SWITCH/PART OF 2273016 REAR GANTRY COVER COLLECTION OF DEFECTIVES START7/23/01 MS5277
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required