LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
CTx00001 Scan Disk Array failure detected by PDS >10 days This Issue was detected by the Digital Services (DS) rule engine. This Issue is only applicable when detected by the Rules Engine and should not be reused in Knowlege objects for normal reactive service. CTx00001 Scan Disk Array failure detected by PDS >10 days This Issue was detected by the Digital Services (DS) rule engine. This Issue is only applicable when detected by the Rules Engine and should not be reused in Knowlege objects for normal reactive service. This rule is triggered when the gesyslog indicates there is less then 8 disk drives in the scan disk array for > 10 days.
Error message
Error: 290014000 scan disk array started with 6 of the configured 8 drives See Long Description for more details Fri Mar 31 21:59:13 2006 Error: 290014000 Host: gevct Process: gre-verify-darc File: gre-verify-darc.cpp Line: 179 The scan disk array was started normally. /dev/md0: RAID-0 active with (6) drives, 256k chunk and 288GB capacity /raw data: testing...399.8MB/sec...done /raw data: 0.0% used, 287.0GB avail /raw data: mounting /dev/md0 filesystem...done Warning: scan disk array started with 6 of the configured 8 drives
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5248406 (replaces 5116147 and 5116147-2) SCSI cables between SDDA (JBOD) and VDARC See LD for Parts Details SCSI Cables between the SDDA (JBOD) and VDARC It is suggested that both cables be ordered and replaced at the same time. Part #: 5248406 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CABLE, SCSI 900mm, VHDCI 68m - VHDCI 68m, with Tin plated Copper Tape FRU: YesStatus: Orderable Comments:Per ECR 2049714, 212008898, 4/7/08 Old FRU Compatible Yes Comments Per ECR 2049714, 212008898, 7/23/08. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5248406 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number ECR2049714 Part #: 5116147 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: CABLE, SCSI VHDCI68m-VHDCI68m x 610mm FRU: Yes Status: Orderable Current: 5116147 Harvested: Not Available Exchange: Not Available Comments: Added per VCT RSPL post M3, ms13452 050426 Part #: 5116147-2 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: CABLE, SCSI VHDCI68m-VHDCI68m x 610mm -B- FRU: Yes Status: Orderable Current: 5116147-2 Harvested: Not Available Exchange: Not Available Comments: Added post M3 to VCT RSPL, ms13452 050426
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.