GE Healthcare · X-ray R&FRevolution
Revolution XRd XQi Error 6C00 6D00 Error 6C00 and 6D00 appears in digital mode after first exposure.
Revolution XRd / XQi Error 6C00 6D00
Symptom
Revolution XRd XQi Error 6C00 6D00 Error 6C00 and 6D00 appears in digital mode after first exposure. Went through Detector and IDC diagnostics on AWS, all would pass.
Error message
Error 6C00 See long description for additional details relating to error display 6C00 "Error Status Received in IDC Prep Reply" error message (HW Status 01) is displayed on the Advantx console. 6D00 "Error Status Received in IDC Prep Reply" error message (HW Status 01) is displayed on the Advantx console. Error 6D00 Acquisition Prep error reported from Digital Workstation See Long Description 6D00Example: Advantx Console6D00 Error Status Received in ADS PREP Reply From the ADS Error Log ,2003-11-04,12:22:21:000,ASC,06D00,ERROR STATUS RECEIVED IN ADS PREP REPLY,,,,AWS,,,1,, ,HWStatus=0001 User=0000 From the Advantx-E Error Description MESSAGES Console Error Message : Acquisition Prep error reported from Digital Workstation. Debug Mode Error Message: ERROR STATUS RECEIVED IN ADS PREP REPLY Debug Mode Numeric Fields: HW: 00H = O.K.01H = Client not available02H = IDC communication error04H = Medical Application error08H = ADS error10H = Sequence errorUSER: N/A MODULE ADS DESCRIPTION The ADS workstation reported an error condition in the Prep Status message sent to the ASC. RECOMMENDED ACTIONS 1. Try to Prep the system again.2. Verify the Medical Application is active on the ADS.3. Ver
Applies to
- Models
- Revolution
- Product
- Revolution XRd Revolution XQi
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…
- Revolution XRd2X Worklist query on "All Systems in this Modality" does not retrieve anything after FMI 10791A is completed due to the default query set to DX.
- Revolution XR/d error 4280 when trying to make exposure to table or wallstand detector
- Revolution XRd 2X The HP Workstation reboots itself.
- Def8000, Def5000, Revolution XRd and XRD2X Latent lead marker image burned into the detector.