Pular para o conteúdo principal
GE Healthcare · CTHiSpeedVCT2300150241127205412230015022230015035512005230015013

Restore Calibration Files from State Media

Symptom

Fastcals failed to complete. Fastcals failed to complete

Error message

Error: 230015024 A corrupt file has been found in the cal database See LD for complete error Tue Sep 20 08:36:51 2005 Error: 230015024 Host: ls16 Process: scanmgr File: cal_db_file_io.c Line: 1983 Function: CAL Processing : SBC Processing A corrupt file has been found in the cal database. The corrupt file has been removed from the cal database and saved for later analysis. Corrupt File: /usr/g/cal_db/kv120/large_sfov/16x0625/large_spot/dasgain5/cal.1.acal Saved File: /usr/g/cal_db/recovery/kv120.large_sfov.16x0625.large_spot.das.cal.1.acal.1127205412

Error: 230015022 Failure loading matrix decon kernel fields in cal module header. See Long Description for complete error Tue Oct 18 07:20:43 2005 Error: 230015022 Host: ctls3 Process: scanmgr File: cal_db_funcs.c Line: 264 Function: CAL Processing : SBC Processing Failure loading matrix decon kernel fields in cal module header. File: /usr/g/cal_db/misc/decon/4x125/cal.large_sfov.1.md

Error: 230015035 Cal_db failure See LD for complete error Tue Oct 18 07:20:43 2005 Error: 230015035 Host: ctls3 Process: scanmgr File: cal_db_file_io.c Line: 762 Cal_db failure, error number = 12, reason: Not enough space Tue Sep 20 08:36:512005 Error: 

Applies to

Models
HiSpeed, VCT
Product
HiSpeed QX/i - GRE Always MDAS 4 QX_P_M4 HiSpeed QX/i - GRE Method of visual identification Small rounded gantry similar in appearance to LS 3.X and 4.X. Always has an MDAS 4 slice Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. xxx
Software
04MW13.6 for HiSpeed QXi with Xtream (GRE) Console - showprods returns 04MW13.6.QX_P_M4_G ## Obsolete by FMI 25365 ## 04MW13.6 for HiSpeed QXi with Xtream (GRE) Console - showprods returns 04MW13.6.QX_P_M4_G ## Obsolete by FMI 25365 ## SYSTEM - HiSpeed QXi with GRE M4.1 SW Collector 5115555 Recon Data Test Patch 5117632 CLASS C 5115559 CLASS M 5115560 showprods | grep LightSpeed = 04MW13.6.QX_P_M4_G Obsolete by FMI 25365 P/N 5137245
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues