Pular para o conteúdo principal
GE Healthcare · CTHiSpeed183319348661855533486521538183318

Scanner Hardware Stopped Scan

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183319 (The HEMRC output current is out of 55.0 percent MAXIMUM tolerance) See Long Description for more details Tue Aug 10 17:25:53 2004 Error: 183319 Host: OBC Process: Generator Function: XRAY GENERATION : Tube Rotor Control Scan: 34866/3/1 Type: Helical Exception Level: Pri/Most Severe The HEMRC output current is out of 55.0 percent MAXIMUM tolerance. Mode = Normal Monitored state = 2 (0=Accel 1=Trans 2=Run state) Expected current = 2.748 A Actual current = 4.387 A

Error: 185553 - Alarm status: 20H (The HEMRC drive has detected a Line Loss. See Long Description for the complete error Tue Aug 10 16:44:06 2004 Error: 185553 Host: OBC Process: Generator Function: XRAY GENERATION : Tube Rotor Control Scan: 34865/2/1 Type: Helical Exception Level: Pri/Most Severe The HEMRC drive has detected a Line Loss. This occurs when the input power to the drive falls below 85% of the nominal Bus voltage. Possible causes: X-Ray tube stator, HEM-IT, HEMRC power supply, .. Alarm status: 20H Or Fri Mar 30 15:21:20 2007 Error: 185553 Function: XRAY GENERATION : Tube Rotor Control Scan: 21538/1/2 Type: Scout Exception Level: Pri/Most Severe The HEMRC drive has detected a Line Loss. This occur

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
D3132T Performix X-Ray Tube used on CT/i ONLY. D3132T Performix X-Ray Tube used on CT/i ONLY Comments: This D3132T tube is used on CTi ONLY. For LightSpeed 1X you must order D3176T. For LightSpeed 2X/3X/4X and HP60 please order D3186T. D3132T Performix X-Ray Tube used on CT/i ONLY Comments: This D3132T tube is used on CTi ONLY. For LightSpeed 1X you must order D3176T. For LightSpeed 2X/3X/4X and HP60 please order D3186T Part #: D3132T Part Type: GP TUBES Part Weight: -6804021.96 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX TUBE FRU: Yes
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues