Unable to Boot Applications.
Symptom
Unable to boot Applications software due to a Host monitor Timeout after 250 seconds See Long Description This was a running system. The tech decided to reboot the system, and then it would never come all the way back up again. Applications software would not come up. After a while, the message "Host monitor Timeout after 250 seconds" was displayed. By viewing the message log from a C-shell using the commands shown below, we found the errors shown below. These same two errors were logged on every failed applications software boot attempt. The two messages are reporting the process "ifcc". Knowing that "ifcc" stands for "Image File Creation and Control", we suspected that the image database was corrupt and would need recovery. We suspected the system was unable to mount the image database completely, and this could be the reason that Applications software would not boot. Looking at the disk partitions using the command "df -k", the /export/home1 image partition was seen to be present (it was 56% full) but perhaps it was corrupt. cd /usr/g/service/log [enter] more gesys* [enter] Fri Sep 1 11:31:19 2006 200002372 signa3 hostMonitor ssProcStart.c 927 The process ifcc took too long to start up. Fri Sep 1 11:32:04 2006 200002352 signa3 hostMonitor ssProcStop.c 812 A HOST_SHUTDOWN was initiated by the death of ifcc.
Error message
200002372 The process ifcc took too long to start up. Fri Jun 10 08:09:19 2005 Error: 200002372 Host: lx-mr Process: hostMonitor File: ssProcStart.c Line: 904 The process ifcc took too long to start up. Hostmonitor Timeout after 250 seconds This message appears on the desktop only, it doesn't get logged in the message log This message appears on the desktop only, it doesn't get logged in the message log. 200002352 A HOST_SHUTDOWN was initiated by the death of ifcc
Applies to
- Models
- Excite
- Product
- 3T Excite HD 12.0 software only
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.