LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 290012001 There are more than XX consecutive bad views - no correction applied . . . exam/series/scan = XXX / XX / XXXX See LD for complete error Thu Feb 9 08:53:27 2006 Error: 290012001 Host: ig3 Process: image_generation File: MissedView.cpp Line: 910 View correction for view 9300 from views 9278, 9322 There are more than 21 consecutive bad views - no correction applied exam/series/scan = 345/4/1

Error: 260118311 Received command ignored. No action defined for current state. see long description for full error description Error: 260118311 Received command ignored. No action defined for current state. Thu Oct 13 13:59:13 2005 Error: 260118311 Host: orp Process: orp_subsys File: gen_exec.c Line: 936 Thu Oct 13 13:59:13 2005 Host : On-Board Rotating Processor Ermes # : 260118311 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 936 Function : No System Function Reported Scan Type : Helical Scan: 2163/4/1 Received command ignored. No action defined for current state. cmd: 30 (0x1e), state: 3 @Exp Cmd:: Tcks:39054526 Exp JEDI Resp:32 Rotor State:5 Last Acq Cmd:7 @Send Prep:: Line:4225 Tcks:39048416 JEDI State:2 Exp JEDI Resp:32 Rotor State:5 Last Acq Cmd

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues