LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Console boot up hangs just after boot up message:S3 AND PAE DO NOT LIKE EACH OTHER FOR NOW, S3 IS DISABLED. The Linux OS fails to start loading Console boot up hangs just after boot up message:S3 AND PAE DO NOT LIKE EACH OTHER FOR NOW, S3 IS DISABLED. The Linux OS fails to start loading. NOTE: The message "S3 AND PAE DO NOT LIKE EACH OTHER FOR NOW, S3 IS DISABLED." is a normal boot up message and not an error. With this issue the console boot simply stops just after this message is posted on the screen. No real error is posted anywhere. Console boot up hangs just after boot up message:S3 AND PAE DO NOT LIKE EACH OTHER FOR NOW, S3 IS DISABLED. The Linux OS fails to start loading. NOTE: The message "S3 AND PAE DO NOT LIKE EACH OTHER FOR NOW, S3 IS DISABLED." is a normal boot up message and not an error . With this issue the console boot simply stops just after this message is posted on the screen. No real error is posted anywhere.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2376564 USB adapter --old-- used with HP computer. Adapter is NOT needed with new USB Trackball. USB trackball ONLY is 2399753 but if you presently have the adapter you must order the USB trackball UPGRADE KIT 5399753 See LD for more info and pictures old 2376564 USB adapter For trackball used with HP computer, you can now order a USB trackball that does not need this adapter. Part number for USB trackball ONLY is 2399753 but if you presently have the adapter you must order the USB trackball UPGRADE KIT is 5399753 Below picture shows HP using adapter. Below picture shows HP WITHOUT adapter Part #: 5399753 See info below in BLUE for Trackball ONLY Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Kit -USB Trackball and bulkhead with USB cable FRU: Yes Status: Orderable Comments: Added per EMC2 RSPL, ms13452 041201 ms13452 Below is trackball ONLY Part #: 2399753 Part Type: GP CONSUMABLES Part Weight: -67999.32 LBR Repairable: No Returnable: No Hazardous Material: N Description: TRACKBALL - 3 BTTN USB for GRE FRU: Yes Status: Orderable Comments: Added per VCT RSPL, ms13452 041201 Included in FMI 25359, ms13452
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required