GE Healthcare · CTLightSpeed11236209111000011236209021142267155
LightSpeed 4.X - GOC2
Symptom
Archiving function for the MOD is grayed out and disabled from use. Archive button on the browser does not respond to cursor clicks.
Error message
Error: 3005 netserver Can't connect with ct01:AQSserver See LD for other examples of this error Tue Aug 9 13:54:58 2005 Error: 3005 Host: ct01 Process: netserver Can't connect with ct01: AQSserver (for message from ct01:QRS.2754, code: 7008, tag: 1123620911) Tue Aug 9 13:54:59 2005 Error: 3005 Host: ct01 Process: netserver Can't connect with ct01: TESTCLIENT.2737 (for message from ct01:ARSserver, code: 10000, tag: 1123620902) NOTE: This error message contains variable information: AQSserver = server variable Another example: Mon Mar 13 09:34:43 2006 Error: 3005 Host: ct01 Process: netserver File: netproc.c Line: 536 Can't connect with ct01: QRS.1688 (for message from ct01:DBWserver.1671, code: 1760, tag: 1142267155) Error: 9001 Unable to set connection - server NETserver host plsu See LD for complete error Wed Nov 24 11:21:07 2004 Error: 9001 Host: plsu Process: film_composer File: application.c Line: 274 Unable to set connection - server NETserver host plsu. Tue May 17 20:23:24 2005 Error: 9001 Host: rhapsmct1 Process: netserver File: application.c Line: 215 Unable to set connection - server ARSserver host rhapsmct1.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) Console 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) Console 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) ConsoleClass C Application Software Set CD Part No. Ver. CD Label CD Part No. Ver. CD Label Set Part No. Apps. CD Part No Apps. CD Label showprods/ Service Desktop Intro. Date Comment 2394897) 1104L.3_ H4.2CLASSC LightSpeed/ HiSpeed QXi Class C Software M4 5111370 5111371 LightSpeed 4.X Applications Software 405L.8_H4.2M4 FW11-04 FMI 25338
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.