GE Healthcare · CTLightSpeedVCT260001039260001044
LightSpeed 4.X - GRE
Symptom
Flash Download Fails
Error message
Error: 260001039 Firmware error: File download to FLASH rejected. See Long Description for complete error. Tue Aug 22 20:38:14 2006 Error: 260001039 Host: OBC Process: HOP File: hop_download.c Line: 792 Running Version Management Tool Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:38:14:635 Log Series: 44 Firmware error: File download to FLASH rejected. The CCB sub-system has rejected the command to commit the file download to FLASH. Msg code: 12 Rejection code: 9 - FLASH memory transfer error Error: 260001044 Firmware error: Application file download failed. Communications with the DCB sub-system is down. See Long Description for complete error Tue Aug 22 20:38:15 2006 Error: 260001044 Host: OBC Process: HOP File: hop_download_state.c Line: 99 Running Version Management Tool Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:38:15:010 Log Series: 45 Firmware error: Application file download failed. Communications with the DCB sub-system is down.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required