Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops

Symptom

Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops. Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops

Error message

Error: 260112014 Touch sensor ? Touch Sensor was PRESSED See Long Description for full error Error: 260112014 Touch sensor ? Touch Sensor was Pressed. Sun Mar 12 15:14:25 2006 Error: 260112014 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9013 Sun Mar 12 15:14:24 2006 Host : Table Gantry Processor Ermes # : 260112014 Exception Class : Secondary Severity : Sec/Soft File : uif_table_tilt_mgr_gt.c Line# : 9013 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 Touch sensor BACK Touch Sensor was PRESSED. Elevation position where touch Sensor was Pressed:0 um. Tilt position where touch sensor was pressed:0 mdeg. Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry. Or Mon Apr 9 09:29:44 2007 Error: 260112014 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 9990 Mon Apr 9 09:29:44 2007 Host : Table Gantry Processor Ermes # : 260112014 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr.c Line# : 9990 Function : PATIENT ANATOMY POSITIONING : Elevation Drive Scan Type : None/Unknown Scan: 317/6/0 Touch sensor FORWARD Touch Sensor was PRESSED. Elevation position where touch 

Applies to

Models
HiSpeed
Product
HiSpeed QX/i - GOC2 103L.5_HSQXIM4 103L.4_HSQXIM4 102L.1_HSQXIM3 HiSpeed QX/i - GOC2 Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types GOC2 List of softwares the product can run 103L.5_HSQXIM4 103L.4_HSQXIM4 - obsolete 102L.1_HSQXIM3 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2277404 Patient Tilt Sensor, Large for Rear Gantry Cover used on HiSpeed QXi, 2.x(Plus), 3.x(Ultra), 4.x(16 Slice), HPower and VCT gantries See Long Description for Part Details 2277404 Patient Tilt Sensor, Large for Gantry REAR Cover Asm. Part #: 2277404 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PATIENT TILT SENSOR, LARGE FRU: Yes Status: Orderable Comments: FLS - H2 GANTRY. COMMON TO MFG MS26561 DSM 1/7/01 REAR LARGE SWITCH/PART OF 2273016 REAR GANTRY COVER COLLECTION OF DEFECTIVES START7/23/01 MS5277
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues