GE Healthcare · CTHiSpeed183296650011831041338018325811478
HiSpeed CT/i 4.X with Indigo and HSA Gantry
Symptom
Scanner Hardware fault during Helical Scan data acquisition Problem is becoming less intermittent and exam sometimes proceeds normally once the resume button is selected. The problem also occurs during warm-up scans and fastcals
Error message
Error: 183296 Monitoring: (Measured 245.5 mA vs Ref 240 mA) See Long Description for the full error Error: 183296 Suite: CT01 Host: OBC Process: Generator File: gen_tech.c 1.36 Method: No Method Line: 529 Function: No System Function Reported Scan: 65001/8/38 Type: Axial Exception Level: Sec/Soft Time: 03:11:20:495 Log Series: 49 Selected Technic: 100 kV, 240 mA, 0 % Mod, Backup Timer 4324. VarmA: (Index: Start 0, Skip 0, Last 0) Last Cmd 240 mA. Monitoring: (Measured 245.5 mA vs Ref 240 mA) . 5 Total Samples, Tube Spit Ctr 0. (Rotor 0x0000ae04, Gen 0x9c19b5ff, Mon 0x00020000 Error: 183104 Cathode transformer pressure switch open See Long Description for complete error Wed Sep 28 08:55:42 2005 Error: 183104 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 696 Function: XRAY GENERATION : Xray Exposure Interlocks Scan: 13380/2/7 Type: Helical Exception Level: Pri/Soft Time: 08:55:42:865 Log Series: 245 Cathode transformer pressure switch open. Error: 183258 KV board MAXIMUM spit rate exceeded Fri Jul 9 14:48:13 2004 Error: 183258 Suite: CT01 Host: OBC Process: Generator File: gen abort.c 1.33 Method: No Method Line: 266 Function: XRAY GENERATION : KV Loop Scan: 11478/3/9
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3132T Performix X-Ray Tube used on CT/i ONLY. D3132T Performix X-Ray Tube used on CT/i ONLY Comments: This D3132T tube is used on CTi ONLY. For LightSpeed 1X you must order D3176T. For LightSpeed 2X/3X/4X and HP60 please order D3186T. D3132T Performix X-Ray Tube used on CT/i ONLY Comments: This D3132T tube is used on CTi ONLY. For LightSpeed 1X you must order D3176T. For LightSpeed 2X/3X/4X and HP60 please order D3186T Part #: D3132T Part Type: GP TUBES Part Weight: -6804021.96 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX TUBE FRU: Yes
- Area
- CT
Full cause & step-by-step resolution