GE Healthcare · CTHiSpeed188415188800
Mulitple ring artifacts in helical images with error
Symptom
Mulitple ring artifacts in helical images with rawkey error See long description for artifact Mulitple ring artifacts in helical images with rawkey error
Error message
Error: 188415 Continuous Bad Raw detected and Scan is going to aborted. Check status LED on DASIFN See Long Description for Full Error. Tue Aug 16 17:28:41 2005 Error: 188415 IRIS RawStore NdbAccess.c 299 DASIFN Error: Continuous Bad Raw detected and Scan is going to aborted. Check status LED on DASIFN Error: 188800 Error occured in check if available, rawkey Error: 188800 Host: HISPEED Process: RawLoad File: API.c Line: 713 Error occured in check if available, rawkey
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2246883 P9233YT DTRF 110M ASSY See LD for Details Part #: 2246883 P9233YT DTRF 110M ASSY Part #: 2246883 Part Type: GP CONSUMABLES Part Weight: 1.10 LBR Repairable: No Returnable: No Hazardous Material: N Description: P9233YT DTRF 110M ASSY FRU: Yes Status: Orderable Current: 2246883 Harvested: Not Available Exchange: Not Available Comments: FLS - DTRF 110M ASSY U/O YMS CT HISPEED ZXI MS08992 9/30/99 2246883 & 2246881 MUST BE REPLACED AS SAME TIME KIT BEING DEVELOPED FOR INSTALLED BASE MS08992 10/4/99 GELS - 2246883 & 2246881 MUST BE REPLACED AT SAME TIME KIT BEING DEVELOPED SEE PART 2258668 TO BE CREATED 99/11FP U/O YMS CT HISPEED ZXI,DTRF 110M ASSY
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.