Pular para o conteúdo principal
GE Healthcare · CTLightSpeed200900025

LightSpeed 4.X - GRE

Symptom

Customer is unable to send to remote host. Customer is unable to send to remote host

Error message

Error: 200900025 Generic Patient Worklist Error , See Long Description for full errors See Long Description for errors The error can be in different contexts per the below Thu Jan 4 10:12:21 2007 Error: 200900025 pct01 WLServer WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 1609, Status: 28 Fatal Unknown DCM ERROR Mon Sep 19 08:28:09 2005 Error: 200900025 ct01 piRxMgmt WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error Source File: WLapiWorklistFile.c, Line: 6038, Status: 3 WLgetTime(): Could not read from /usr/g/db/patientInfo/Update.db. PS000007990.db for reading. Error: 200900025 Host: ls08 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLS_mfm.c, Line: 1465, Status: 23 Parse Failed : Patient Worklist Manager HIS(40)(3) :-104 Error: 200900025 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 293, Status: 19 DICOM Association Inactivity Time-out Tue Sep 26 09:51:49 2006 Error: 2

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues