GE Healthcare · CTLightSpeed182827182826182889182825
Scanner hardware reset and flash download fails
Symptom
Scanner hardware reset and flash download fails
Error message
Error: 182827 TNC Start Input to ETC FAILED. Possible Communication Problem. Gantry Push Button, Foot Pedals, and Remote Tilt Might NOT Function. Mon May 2 15:51:45 2005 Error: 182827 Host: ETC Process: Gantry Display File: gd_gantryCtrls.c Line: 452 Running Version Management Tool Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 15:51:45:790 Log Series: 42 TNC Start Input to ETC FAILED. Possible Communication Problem. Gantry Push Button, Foot Pedals, and Remote Tilt Might NOT Function. Error: 182826 Communication Error: Communication Packet with the GANTRY DISPLAY. Open Long Description for full error Wed Dec 22 20:49:26 2004 Error: 182826 Host: ETC Process: Gantry Display File: gd_tnc_driver.c Line: 477 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:48:40:485 Log Series: 31 Communication Error: Communication Packet with the GANTRY DISPLAY. Message Code: 2. (Data = 0x20, 0x0, 0x0, 0x0). Error: 182889 The TNC has INVALID Application Code in FLASH memory. New Code needs to be Downloaded via the Flash Download Tool. Mon May 2 11:15:55 2005 Error: 182889 Host: ETC Process: Ga
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - Octane sw_version: 405I.2_H4.0M5 LightSpeed 4.X - Octane Gantry Model # 2339985 Console Model #'s 2341923 and 2341923-2(D3D) check_config shows LightSpeed 16 / LightSpeed 16 Product: LightSpeed16 sw_version: 405I.2_H4.0M5 or newer machine_type: Octane host_id: 3232297858 tube_type: 15 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2256730-3 Display assembly used on 2.X/3X/4X5X/7X See long description for details. Part #: 2256730-3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: H-POWER COMPATIBLE GANTRY DISPLAY FRU: Yes Status: Orderable Comments: FLS - H-POWER COMPATIBLE GANTRY U/O CT H POWER DISPLAY
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required