GE Healthcare · CTHiSpeed
How to disable / enable PPS ( Performed Procedure Step )
Symptom
How to disable / enable PPS ( Performed Procedure Step )? How to disable / enable PPS ( Performed Procedure Step )
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Software
- 11.00 Software for HiSpeed DX/i, FX/i, LX/i, ZX/i, NX/i Series HiSpeed LX/i, FX/i, DX/i, ZX/i Version 11.00 is a Linux based software that will replace the current IRIX based software due to the end of life SGI O2 computer. The features of the Version 11.00 are almost the same as current HiSpeed See LD for details CT HiSpeed DX/i, FX/i, LX/i, ZX/i, NX/i Series V/R 11 No Class C Software 5142789 −− INSITE SOFTWARE 11.00 CD−ROM HOST NP Tab distributed via Tab# 182 Refer to YMS S/N 153 which can be found on Hino CT Technical Publications online at: http://jptyoiis01.ap.health.ge.com:8000/ct/ Always use the the most appropriate documentation for your system. The following was taken from Rev 1 of the service note and is provided for your reference: SERVICE NOTE S Feb. 28, 2006 Page 1 of 5 FILE TITLE CT HiSpeed DX/i, FX/i, LX/i, ZX/i, NX/i Series YMS–SN153 Restricted to General Electric Medical Systems (GEMS) personnel only. Permission to use this Restricted Service Software and related documentation (hereinafter called the ”Material”) by persons other than GE Medical Systems employees is prohibited. This Material is the property of GEMS and contains information which is restricted to use by GEMS Manufacturing, Engineering and Service personnel. Any reproduction in whole or in part is strictly prohibited. Neither this material nor any information contained herein shall be disclosed to anyone outside of GEMS Manufacturing, Engineering and Service personnel. CT HiSpeed DX/i, FX/i, LX/i, ZX/i, NX/i Series V/R 11 Release Note APPLIES TO : CT HiSpeed LX/i, FX/i, DX/i, ZX/i series, NX/i series. PURPOSE : HiSpeed LX/i, FX/i, DX/i, ZX/i Version 11.00 is a Linux based software that will replace the current IRIX based software due to the end of life SGI O2 computer. The feature of the Version 11.00 is almost same as current HiSpeed LX/i, FX/i, DX/i, ZX/i but some new options will become available. HiSpeed NX/i Version 11.00 is also a Linux software due to the end of life of SGI O2 computer and Graphic Card of Version 8.10 PC. The feature is same as current HiSpeed NX/i Version 8.10. And, it is almost same as current HiSpeed NX/i Version 9.00 but some new options will become avairable. This Service Note has the following purposes; To inform the service personnel (FE, ACE, RSE/ZSE and TOM), of new features, some limitations and errata and bugs which are fixed in V/R11 software. To enable the service personnel (FE, ACE, RSE/ZSE and TOM), to avoid the unnecessary visits to the site to replace components when the trouble is in fact just a bug, and to save thus the labor and money. Note: FE: Field Engineer ACE: Account Engineer RSE/ZSE: Region/Zone Support Engineer TOM: Technical Operating Manager This Service Note is NOT intended as a handout to customers. NEVER GIVE THIS SERVICE NOTE DIRECTLY TO CUSTOMERS. PART NUMBER INFORMATION : V/R 11 Application CD–ROM: 5142777 V/R 11 InSite CD–ROM: 5142789 New Features: The following applications are avairable this version as option, compare with Version 9.00 and 10.00. Functool (Standard option) Volume Analysis2 Volume Rendering2 Navigator2 CT Perfusion2 Advanced Vessel Analysis (HiSpeed NX/i Series only) CT Colono (HiSpeed NX/i Series only) Note For Service: Feature of the service tools in Common Service Desktop are the same as Version 9.0 and 10.0. FRU structure in operator console was changed. Please refer to the latest Renewal Parts Manual. . Note When you replace the host computer, unlike O2 computer, option keys are not inherited from old computer by “savestate” and “restorestate”. Also, it is not possible to install options to new computer by using original option key MOD. If you need to replace the host computer, please contact to region OLC and get new option key. New class M software (InSite software) was released for this version. The part number is 5142789 (Tab#:287). Pioneer MOD Option (B76312GE) is not available on this product. BUG FIX : FOR V/R 11 While saving the 3D model, high system load causes no operation of the system. (YMSct 03432 ) When ReconEngine error occurs during SmartRecon, the system cannot be resumed. (YMSct 03433 ) Hoistid is changed for high security . For the system with V/R 8.10, the current optional key MOD cannot be used. (YMSct03458) For the system with Japanese language and special annotation, when clicking on InstallOption menu, the image annotation does not appear. (YMSct03683) ScanRx crash (YMSct03818, YMSct03436) For the two or more Prospective Multi Recon (Recon2/Recon3) series, AutomA cannot be set. (YMSct03808, YMSct03470) Need to take IIP 3.2 Patch (YMSct03354) MTF Survey: Unable to move cursor. (YMSct03746) Image Profile: FWHM does not display HMW value (YMSct03747) Unable to start scan analysis (PQR#13038864) The cradle stop during helical scan, but scan do not stop. (PSR#13016342) RawStore crashes during start–up. (YMSct03459) The F4 (PrintSeries) works incorrectly; the F4 key install the image on the manual film composer. (PQR#13012486) The Cut–off image on the film when setting GSE on (CSO#417387) The Denta popup window locks mouse cursor when clicking on the middle button of the mouse, so that the system must be rebooted. (PQR313009705) VR conflict of PPS ID (0040, 0253) (YMSct03471) TubeSpits log file caused ScanCtrl to crash.(YMSct03902: CSO#1–141926371) Limitation and Errata : With Archived MOD set on the system, restorestate procedure can be performed but it is actually not performed. (YMSct03825) The DBPCI#0 power–on test failed during startup after application shutdown. (YMSct03764) Wrong WW/WL are set for preset keys of reformat and voxtool at first. Once click [Save as Defaults], WW/WL become to be correct. (YMSct03920) Occassionally Calvector of ScanAnalysis cannot run, depending on rawdata to be selected. This phenomenon will occurs when “ /usr/g/data/model.macine.exam.series.raw” is 28 or 36 characters. Workaround: CalVector can be seen i GSA/VEctorConvert. ( YMSct03939) Recon timeout occurs during scans, so that a portion of images cannot be reconstructed. (YMSct04003) When system reboots during reconstruction, reconstruction cannot be performed after startup. (YMSct04002) The image saved in color cannot be sent to the sun–based AW (V/R 4.0). The SSAVE image saved in color only cannot be sent to the AW (V/R 4.0 or lower). However, when archiving then restoring the images saved in color, they can be sent. The 3D image saved in B/W can be sent. (YMSct03962) Function key behavior becomes same as Function key + [Shift] key (to set WW/WL), after pressing [F4] + [Shift] key. If this issue happens, please press [Shift] key with mouse on display viewport and reset the correct value on UsePrefs. (YMSct04008)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required