GE Healthcare · MRExciteSigna224830510197220928422547862224667
Application Software does not complete the boot process with Errors 2248305 and 2254786 Internal Software Exception clas…
Application Software does not complete the boot process with Errors 2248305 and 2254786 Internal Software Exception class and Universal Power monitor error
Symptom
Application Software does not complete the boot process with TPS Download failure
Error message
2248305 It may be necessary to perform a TPS Reset. An SCT packet send failed. Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Internal Software Error. 2248305 lx-mr NSP SCP:scp_send_pkt 10 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Internal Software Error. It may be necessary to perform a TPS Reset. An SCT packet send failed. Packet opcode: 10197 Status: 2209284 2254786 The Universal Power Monitor 2 Has Detected an Invalid Configuration. Source of Fault is NB Detector Board RF Cable Missing. See Long Description for full error and extended log... NOTE: The errors below were copied from a 3.0T 14xM5 system: Date Time ErrorCode Process File Line Message Jan 24 Thu 17:11:21 2254786 NSP SCP:UPM 894 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: Unknown Coil: Unknown Scan: -1/-1 The Universal Power Monitor 1 Has Detected an Invalid Configuration. Source of Fault is NB Detector Board RF Cable Missing.-> Jan 24 Thu 17:11:21 2254786 NSP SCP:UPM 894 Exception Class: Unknown Severity: Unknown Function: RF: R
Applies to
- Models
- Excite, Signa
- Product
- Excite HDe. For Hino HDe 14.0 and HDe 15.0 Software Systems only
- Software
- HDe 14.0 For Hino Excite HDe 14.0 systems only.
- Component
- SecondOpinion Image Compute Node 5127452 See comments in Resolution Concept for second opinion requirements before ordering this part.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.