GE Healthcare · CTLightSpeed244584178570244586260001008

Collimator/DAS reset failed

Symptom

Unable to scan with a message on screen that says: Collimator/DAS reset failed.

Error message

Error: 244584 Collimator/DAS reset failed See Long Description for complete error Error: 244584 Host: qx-ct Process: fwmgr File: HwManager.c Line: 1536 Collimator/DAS reset failed.

Error: 178570 Coll/Das controller reports failure in initializing tasks See Long Description for complete error Mon Mar 28 03:39:48 2005 Error: 178570 Host: ct04 Process: fwmgr File: HwSetUp.c Line: 3178 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 OBC_SS timeout: Coll/Das controller reports failure in initializing tasks.

Error: 244586 the following hardware subsystems reported a failure when initializing: OBC SS (Coll/Das) See the Long Description for the complete error code Error: 244586 Host: qx-ct Process: fwmgr File: HwSetUp.c Line: 2235 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 The following hardware subsystems reported a failure when initializing: OBC SS(Coll/Das)

Do Not Use - use one of the other Error: 260001008 The OBC failed to connect with the ? (DCB and/or the CCB) sub-system in the allotted time Open Long Description to see error example Mon Mar 28 03:39:48 2005 Error: 260001008 Host: OBC Process: 

Applies to

Models
LightSpeed
Product
LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2225218 DCB HOUSING ASM for SDAS See LD for details Part #: 2225218 Part Type: GP REPAIRABLES Part Weight: 0.66 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: DCB HOUSING ASM (SDAS) FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2225218 Harvested: Not Available Exchange: Not Available Comments: FLS - DCB ASM, P/N 2225218 7/31/02- C2R COMPLETED PER M DIGGINS, CHANGE ORDER TO T3202KJ BEFORE SHIPPING. MS12464 CAN'T ORDER DAS ASSY SEE T3202KJ 1/2/02 VEN HAS 20 PC MINIMUM BUY PER PO AND 60 DAY LEAD TIME. MS09121 *** CD & S NOTE **** BEFORE REPLACING THE SDAS DAS CONTROL BOARD (DCB), MEASURE THE +5V ON THE BOARD FROM TP-1 - TP-2. VERIFY THIS IS ABOVE4.8 VOLTS. VOLTAGE LOWER THANTHIS MAY CAUSE INTERMITTENT OPERATIONS. IF THE VOLTAGE ISOK ON THE CONVERTER CARD CHASSCHASSIS, YOU MAY HAVE A CABLE PROBLEM. MS30863 5/31/02 GELS - CSO0111459 FRANCE F-45071720002 /04/01/TS FIBER OPTIC FREQ 50 MHZ / NEEDS DIP BOARD 2275604 OR 2245261 PDB 02/01/21,DCB HOUSING ASM
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.