GE Healthcare · MR2225113

HFO Coldhead Cycling Is Disabled During Scan

Symptom

Cold Head Cycling Is Disabled During Scan. The system is an OpenSpeed running HFO3 M4 software. Coldhead cycling is disabled, so the 2 stage coldhead runs during scanning. There are SHEM communication errors in the /usr/g/service/log/tcuErrors log. I can telnet between the SHEM and the system, so it looks like network connection is good. The MAGNET_MONITOR_IP line is configured with the SHEM IP address in /etc/hosts on the MR. Ran /MVServe/bin/Net_Config on the SHEM. Looks OK. See long description for more info: /usr/g/service/log/tcuErrors log: 12/23/2003 11:49: PMHost.cc:476 CH Status unchanged: Previous Status = Communication Fail, Current Status = Communication Fail 12/23/2003 11:51: PMColdHead.cc:29 Comm with SHeM failed errors in gesys log: Tue Dec 23 12:17:25 2003 Error: 2225113 Host: lx-mr Process: NSP File: HPC_PORT_ID:hpc_change_state Line: 40 ColdHead switching not enabled during scan. HPC was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains. {sdc@lx-mr}[1] getver Hostname : lx-mr Build number for MrpApps is HFO3.29I_M4_0320.a Build number for PostSdC is HFO3.29I_M4_0320.a Build number for cclass is HFO3.29I_M4_0320.a Build number for driverSupport is HFO3.29I_M4_0320.a Build number for insite is HFO3.29I_M4_0320.a Build number for install is HFO3.29I_M4_0320.a Build number for os_cd is 6_15.4.a Build number for pc is HFO3.29I_M4_0320.a MR Software release: H.F.O.3.0320a

Error message

2225113 ColdHead switching not enabled during scan. Tue Dec 23 12:17:25 2003 Error: 2225113 Host: lx-mr Process: NSP File: HPC_PORT_ID:hpc_change_state Line: 40 ColdHead switching not enabled during scan. HPC was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains.

Applies to

Product
Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.