HFO Coldhead Cycling Is Disabled During Scan
Symptom
Cold Head Cycling Is Disabled During Scan. The system is an OpenSpeed running HFO3 M4 software. Coldhead cycling is disabled, so the 2 stage coldhead runs during scanning. There are SHEM communication errors in the /usr/g/service/log/tcuErrors log. I can telnet between the SHEM and the system, so it looks like network connection is good. The MAGNET_MONITOR_IP line is configured with the SHEM IP address in /etc/hosts on the MR. Ran /MVServe/bin/Net_Config on the SHEM. Looks OK. See long description for more info: /usr/g/service/log/tcuErrors log: 12/23/2003 11:49: PMHost.cc:476 CH Status unchanged: Previous Status = Communication Fail, Current Status = Communication Fail 12/23/2003 11:51: PMColdHead.cc:29 Comm with SHeM failed errors in gesys log: Tue Dec 23 12:17:25 2003 Error: 2225113 Host: lx-mr Process: NSP File: HPC_PORT_ID:hpc_change_state Line: 40 ColdHead switching not enabled during scan. HPC was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains. {sdc@lx-mr}[1] getver Hostname : lx-mr Build number for MrpApps is HFO3.29I_M4_0320.a Build number for PostSdC is HFO3.29I_M4_0320.a Build number for cclass is HFO3.29I_M4_0320.a Build number for driverSupport is HFO3.29I_M4_0320.a Build number for insite is HFO3.29I_M4_0320.a Build number for install is HFO3.29I_M4_0320.a Build number for os_cd is 6_15.4.a Build number for pc is HFO3.29I_M4_0320.a MR Software release: H.F.O.3.0320a
Error message
2225113 ColdHead switching not enabled during scan. Tue Dec 23 12:17:25 2003 Error: 2225113 Host: lx-mr Process: NSP File: HPC_PORT_ID:hpc_change_state Line: 40 ColdHead switching not enabled during scan. HPC was told to initiate a scan with the ColdHeads on. Image degradation is likely while this condition remains.
Applies to
- Product
- Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.