GE Healthcare · CTLightSpeed26000240348361114001260012602260002358
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
"Scan hardware Stopped Scan" with DAS power errors. "Scan hardware Stopped Scan" with DAS power errors
Error message
Error: 260002403 The Data Acquisition System Has Detected An Error In The +/- 12V Analog DAS Power Supply. See Long Ddescription for error variation Thu Apr 13 06:29:45 2006 Error: 260002403 Host: DAS Process: DCB Firmware File: pwrtst.c Line: 178 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 48361/2/4 Type: Axial Exception Level: Sec/Soft Time: 06:29:44:870 Log Series: 97 The Data Acquisition System Has Detected An Error In The +12V Analog DAS Power Supply.^B Measured: 0 mV, Expected range: 11400 to 12600 mV Mon May 19 00:25:21 2008 Error: 260002403 Host: DAS Process: DCB Firmware File: pwrtst.c Line: 233 Function: DATA ACQUSITION : Scan Data Acquisition Scan: 0/0/0 Type: None/Unknown Exception Level: Sec/Soft Time: 00:25:22:315 Log Series: 28 The Data Acquisition System Has Detected An Error In The -12V Analog DAS Power Supply.^B Measured: -12602 mV, Expected range: -12600 to -11400 mV Error: 260002358 Scan ABORT -- DAS Has Detected An Error. Scan Setup Errors Prevent The Data Acquisition System From Being Able To Scan. (See Previous Log Entries.) See Long Description for error example Tue Dec 7 07:23:22 2004 Error: 260002358 Host: DAS Process: DCB Firmware File: scan
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required