Pular para o conteúdo principal
GE Healthcare · CTLightSpeed

LightSpeed 4.X - GRE

Symptom

What is the Touch Sensor BYPASS Connector Plug used when servicing CT LightSpeed class Tables Checkmark this and see "component" for part number. What is the ByPass Connector plug used when servicing CT LightSpeed class Tables This Connector Plug is utilized on either side of the table and used to ByPass the Table Touch Sensor switches.

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-297805G1 Table ByPass JUMPER CONN See LD for details and to make sure correct part number ordered 46-297805G1 Table BYPASS JUMPER CONN Part #: 46-297805G1 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: JUMPER CONN. FRU: Yes Status: Orderable See differences between G1 and G2 jumpers below. Wiring also shown for the two style jumpers.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues