GE Healthcare · CTHiSpeed200501536200105007200001821200501520200000019

Customer can not page between scout views when using Show Localizer

Symptom

Customer can not page between scout views when using Show Localizer See Long Description for details Customer can not page between scout views when using Show Localizer with Errors 200501536 , Previous message error was of type UIF State Info Action Request with sequence number 538 and 200105007 Scanner software failed to process message with status 200501520 while Enabling Landmark Wed Apr 5 15:24:48 2006 Error: 200501520 Host: bhicct1 Process: scanRx File: uifIpcMgrScanRx.c Line: 6812 Function: Data Acquisition : OC Processing Received message from service uif_state_info with out of order sequence number, expected 538 received 0 Wed Apr 5 15:24:48 2006 Error: 200501536 Host: bhicct1 Process: scanRx File: uifIpcMgrScanRx.c Line: 6834 Function: Data Acquisition : OC Processing Previous message error was of type UIF State Info Action Request with sequence number 538 Wed Apr 5 15:24:48 2006 Error: 200105007 Host: bhicct1 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition : OC Processing Scanner software failed to process message with status 200501520 while Enabling Landmark

Error message

Error: 200501536 Previous message error was of type Get Calibration Status Request with sequence number 6159 See Long Description for the full error Thu Jun 9 08:19:31 2005 Error: 200501536 Host: pmct Process: scanRx File: uifIpcMgrScanRx.c Line: 7070 Function: Data Acquisition: OC Processing Previous message error was of type Get Calibration Status Request with sequence number 6159

Error: 200105007 Scanner software failed to process message with status 200001821 while Getting Cal Status See Long Description for the full error examples. status and process may change Thu Jun 9 08:19:31 2005 Error: 200105007 Host: pmct Proces: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition: OC Processing Scanner software failed to process message with status 200001821 while Getting Cal Status Another example: Wed Apr 5 15:24:48 2006 Error: 200105007 Host: bhicct1 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition : OC Processing Scanner software failed to process message with status 200501520 while Enabling Landmark Another Example Tue Jun 24 05:41:44 2008 Error: 200105007 Host: rhapby26 Process: scanRx File: SubSystemIf.c Line: 650 Function: Data Acquisition :

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.