Explanation for Multicoil Bias Fault with Head & Body T/R Faults 2249149 and 2249151

Symptom

Explanation for Multicoil Bias Fault with Head & Body T/R Faults: Head and Body Path Open Unable to scan using a certain phased array coil. The strange thing is we are always seeing Body Path Open and Head Path Open T/R Faults at the same time as a Multicoil Bias Fault whenever we attempt a scan using this coil. We expect only the Multicoil Bias fault if the problem is with this coil. Why are we also getting the Head & Body T/R Faults? What is the real problem we should be looking at here? See Long Description for the error log. Mon Dec 12 19:42:36 2005 2252293 MRISB1 NSP SCP:DCB 1986 The Driver Module Has Detected a Fault. Details of the Fault can be found in other error messages.-> Mon Dec 12 19:42:36 2005 2252301 MRISB1 NSP SCP:DCB 779 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 Channel 2 of 16, counting from 1 Value: 197 mA Limit: 198 mA Mask of all failed channels: 0x2-> Mon Dec 12 19:42:36 2005 2249149 MRISB1 NSP SCP:../TrDriverMdsHWO.cpp 1286 T/R driver fault, head path open Possibly a disconnected cable between the driver board and the head T/R network, or an open diode in the head T/R switch. Mon Dec 12 19:42:36 2005 2249151 MRISB1 NSP SCP:../TrDriverMdsHWO.cpp 1302 T/R driver fault, Body Path open Possibly a disconnected cable between the driver board and the body T/R network, or an open diode in the body T/R switch.

Error message

2249149 T/R driver fault, head path open. 2249149 Host: LDEX Process: NSP File: SCP:../TrDriverMdsHWO.cpp Line: 1286 T/R driver fault, head path open. Possibly a disconnected cable between the driver board and the head T/R network, or an open diode in the head T/R switch.

2249151 T/R driver fault Body Path open Wed May 18 07:48:37 2005 Error: 2249151 Host: cv-mr Process: NSP File: SCP:../TrDriverMdsHWO.cpp Line: 1302 T/R driver fault, Body Path open^A Possibly a disconnected cable between the driver board and the body T/R network, or Wed May 18 07:48:37 2005 Error: 2249151 Host: cv-mr Process: NSP File: SCP:../TrDriverMdsHWO.cpp Line: 1302 T/R driver fault, Body Path open. Possibly a disconnected cable between the driver board and the body T/R network, or

Applies to

Models
Excite, Signa
Product
Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
Software
11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.